AO Smith® Conservationist® Burkay® 100122606 HW-670 Hydronic Heating Boiler, Natural Gas Fuel, 670000 Btu/hr Input, Bronze/Brass Housing, NPT, Electronic Ignition
AO Smith®
AO Smith® Conservationist® Burkay® 100122606 HW-670 Hydronic Heating Boiler, Natural Gas Fuel, 670000 Btu/hr Input, Bronze/Brass Housing, NPT, Electronic Ignition
1442415MFG #: 100122606
$22,580.34
/ ea
AO Smith® Conservationist® Burkay® Hydronic Heating Boiler, Series: HW-670, Natural Gas, 670000 Btu/hr Input, NPT, Electronic Ignition, Bronze/Brass Housing, 27 in Dia x 68-5/16 in H
All non-ferrous waterways - All castings are made of bronze or brass
All water tubes are made from copper
Brazed joints or flare union construction make the heater immune to the effects of thermal shock and thermal cycling
The Burkay® boiler provides one of the smallest foot prints in the industry
Efficient copper coil combustion chamber the combustion chamber is a heat exchanger formed from a two passage coil of tightly wound continuous copper tube
Water circulating through this coil captures radiant heat
A wrap of insulation on the outside of the coil retains the heat captured by the circulating water, up to 82% efficient
Copper heat exchanger - Directly above the coil and the main burner is a compact, horizontal, copper fin tube heat exchanger
The flue gases must pass through this efficient heat exchanger before leaving the boiler
This unique Burkay® coil and heat exchanger design provide maximum heat transfer and proven field durability
Models meet the thermal efficiency and standby loss requirements of the US department of energy and current edition of ASHRAE/IESNA 90.1
Burkay burner maximizes efficiency - The patented Burkay® burner designed to provide the highest level of primary air to 71 individual orifices while adding sufficient secondary air for proper combustion
Gas valves - Slow opening redundant gas valves ensure smooth light-off without flame roll-out or pilot outage
Thermal balancer - Factory supplied for use with primary secondary heating systems
Cycles the secondary pump with the burner, but delays pump shut off at the end of the heating cycle to remove usable heat from the boiler
Virtually eliminates stand-by heat losses at the boiler
Automatic safety controls and electronic ignition - Proven pilot ignition system provides flame failure response in under 1 second
Redundant high limit controls and gas valves assure safe shut off in the event of overheating or flame failure
To compensate for the effects of high altitude areas above 2000 ft, the input, output and heating load ratings should be reduced approximately 4% for each 1000 ft above sea level
CAT-I RM, ASME approved, hydrostatically tested and certified for 160 psi
Standard/Approvals: AHRI Certified|ASHRAE/IESNA 90.1|ASME H|ASME Specified T&P Relief Valve|CSA Certified|CSA Low Lead Content|CSA Star Design Certified
INCLUDES: 30 psi Temperature and Pressure Relief Valve
WARRANTY: 10 Years Limited Coil, Heat Exchanger and Burner