Dormont® SuprSafe® 0241007 50 Series, 50-5152-24 Gas Connector, 1 in, MNPT x FNPT, 581800 Btu/cu-ft, 24 in L, Stainless Steel

191385 MFG #: 0241007
$220.00 / ea
  • Diameter: 1 in ID x 1-1/4 in OD
  • Domestic/Import: Domestic
  • End Style: MNPT x FNPT
  • Flow Rate: 581800
  • Length: 24
  • Material: Stainless Steel
  • Nominal Size: 1
  • Series: 50 Series

Dormont® SuprSafe® Gas Connector, Series: 50, 1 in Nominal, MNPT x FNPT, 581800 Btu/cu-ft, 1 in ID x 1-1/4 in OD Dia, 24 in Length, Stainless Steel

This 1 1/4 in OD, 1 in ID, durable, corrosion resistant stainless steel gas connector is configured with 1 in MIP x 1 in FIP adapters and is 24 in in length. Designed with safety in mind, this CSA approved gas connector is commonly used for the installation of high BTU appliances such as rooftop units and mobile home gas meters.

QTY
  • Features
  • Tubing annealed, 304 stainless steel (ASTM A240)
  • Brass or plated steel flare nuts and adapter
  • Optional coating heavy-duty, antimicrobial, hot-dipped gray PVC (41, 51 and 61 series)
  • Coating will not hold a flame
  • Approved for indoor/outdoor use with stationary gas appliances/equipment
  • -40 to 150 deg F operating temperature with adapters
  • 100% factory leak tested
  • Exclusive No-Neck® design increases flexibility
  • More corrugations per inch increase flexibility and extend service life
  • When installing a new appliance or when an existing appliance is moved to a new location a NEW gas connector must be per manufacturer's installation instructions and product standards
  • Eliminates the need for pipe nipples, 90's and elbows
  • Pre-fabricated gas connector means no field threading, cutting or assembly of CSST fitting and tubing
  • Btu/hr 1.55 SG, 2500 BTU/cu-ft at 0.5 in water column pressure drop straight length capacity for LP gas
  • 930880 btu/cu-ft for LP gas
  • Designed for occasional movement after installation
  • City of New York MEA No 376-92-M
  • Approved by the Commonwealth of Massachusetts Board of State Examiners of Plumbers and Gas Fitters - connector length may not exceed 48 in
  • BTU/hr 0.64 SG, 1000 BTU per cu-ft at 0.5 in water column pressure drop straight length capacity for natural gas
  • Boilers, gas meters, furnaces, commercial water heaters, gas packs/rooftop HVAC units, tankless water heater, stationary standby generators
  • All installations must completely comply with all Dormont manufacturing company warnings and instructions, national, state and local codes and all applicable ansi standards
  • Standard/Approvals: ANSI Z21.24/Z21.75|ASTM A240|CSA 6.10/6.27|UL2200-2015|UL536|PROP65: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm.