WATTS® F111585 957-FS Inline Backflow Preventer, 3 in Nominal, Flange Joint End Style, Outside Stem and Yoke Resilient Seated Gate Valve, Stainless Steel Body, Reduced Pressure Zone, 7.5 fps Flow Rate, Domestic
WATTS®, F111585, Backflow Preventer, Inline, Series: 957-FS, 3 in Nominal, Flange Joint End Style, 175 psi Pressure, 33 to 140 deg F, 7.5 fps Flow Rate, Outside Stem and Yoke Resilient Seated Gate Valve Ball Valve/Gate Valve, Reduced Pressure Zone Backflow, Media: Water, Stainless Steel Body, 31-3/4 in W x 10-1/2 in D Dimensions, Domestic

- Replaceable check disc rubber
- Groove couplings for ease of installation and pipe alignment
- Compact design allows small enclosures to be used
- Features a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve
- 304 (Schedule 40) stainless steel housing and sleeve
- The maximum working pressure is 175 psi (12.06 bar)
- Standard/Approvals: 1-UL Listed|ASSE 1013|CSA B64.4|cULus Classified|FM Approved|NSF/ANSI 691-G|PROP65: Cancer and Reproductive Harm www.P65Warnings.ca.gov
- WARRANTY: 1 Year
WATTS®, F111585, Backflow Preventer, Inline, Series: 957-FS, 3 in Nominal, Flange Joint End Style, 175 psi Pressure, 33 to 140 deg F, 7.5 fps Flow Rate, Outside Stem and Yoke Resilient Seated Gate Valve Ball Valve/Gate Valve, Reduced Pressure Zone Backflow, Media: Water, Stainless Steel Body, 31-3/4 in W x 10-1/2 in D Dimensions, Domestic
This 3 inch reduced pressure zone assembly backflow preventer help stop the reverse flow of liquids due to backpressure or backsiphonage, where potential health hazard exists. This extremely compact and lighter than a traditional designed assembly is approved for horizontal installation as long as the backflow assembly is installed in accordance with the direction of the flow arrow. This assembly consists of a stainless steel body with a quick access sleeve, torsion spring check valves, resilient seated gate valves with outside stem and yoke, test cocks, and a corrosive resistant stainless steel bottom mounted pressure relief valve. This backflow assembly contains a flood sensor with SentryPlus Alert(R) technology to detect excessive water discharges from the relief valve. When activated through an add-on sensor connection kit, the flood sensor relays a signal that triggers notification of potential flooding to service personnel. The add-on sensor connection kit is available for building management systems and cellular communication.
- Brand: WATTS®

WATTS® F111585 957-FS Inline Backflow Preventer, 3 in Nominal, Flange Joint End Style, Outside Stem and Yoke Resilient Seated Gate Valve, Stainless Steel Body, Reduced Pressure Zone, 7.5 fps Flow Rate, Domestic
WATTS®, F111585, Backflow Preventer, Inline, Series: 957-FS, 3 in Nominal, Flange Joint End Style, 175 psi Pressure, 33 to 140 deg F, 7.5 fps Flow Rate, Outside Stem and Yoke Resilient Seated Gate Valve Ball Valve/Gate Valve, Reduced Pressure Zone Backflow, Media: Water, Stainless Steel Body, 31-3/4 in W x 10-1/2 in D Dimensions, Domestic